Details
180kW DC Fast Charging for Public and Commercial EV Infrastructure
Safe, fast and reliable DC fast charging with CHAdeMO, CCS, GB/T and optional AC Type 2 configurations.
SETEC Power 180kW EV Fast Charging Station, model SET750-180Y, is a high-power DC fast charger designed for public charging networks, service stations, highway corridors, busy urban areas, fleet operators and EV infrastructure providers.
The charger supports multiple connector configurations including CHAdeMO, CCS, CCS / CHAdeMO + CCS, CHAdeMO + CCS + Type 2 and GB/T. CCS Combo 1 is commonly used for American EVs, CCS Combo 2 for European EVs, CHAdeMO for Japanese and selected Korean EVs, and GB/T for Chinese EVs.
With multi-protocol charging, optional 2 DC simultaneous charging, 10" touchscreen, RFID access, OCPP 1.6 JSON, 4G / Ethernet / WiFi communication and payment / billing readiness, SETEC 180kW is built for serious EV charging infrastructure.
Application
SETEC 180kW DC Fast Charging Station is suitable for service station operators, public corridor charging along highways, busy urban areas, commercial fleet operators, EV infrastructure operators and EVSE providers.
It is intended for EV charging sites where high charging power, multi-standard connector support, secure user access, reliable operation and payment / billing readiness are required.
Safe, Fast and Reliable
Built-In Safety Measures
Includes input protection, grounding detection, emergency stop, output over-current protection and output short-circuit protection.
Flexible Multi-Protocol Design
Supports GB/T, CHAdeMO, CCS Combo 1 or CCS Combo 2 and optional AC Type 1 / Type 2 charging configurations.
Optional 2 DC Simultaneous Charging
Optional configuration supports two DC charging sessions at the same time, subject to charger configuration and site requirement.
10" Touchscreen Operation
Touchscreen displays remaining charging time, failure information, parameter settings and charging status.
RFID and Payment Ready
RFID card reader supports tap-to-start / stop charging, with payment and billing platform options for commercial use.
Connected Charger
Supports OCPP 1.6 JSON with 4G, Ethernet and WiFi network communication.
Key Features
Charger Features
- User-friendly interface
- Durable enclosure for commercial use
- Flexible multi-protocol design
- GB/T, CHAdeMO and CCS Combo 1 or CCS Combo 2 compatible
- Type 1 / Type 2 AC charger option, 22kW or 43kW
- Cable or socket option for AC Type 2 / Type 1
- Wide operating temperature range from -25°C to +65°C
- Data management and metering options
Operation and Maintenance Features
- OCPP 1.6 or future version support
- WiFi, 4G and GSM optional
- Holder locker optional
- Multi-language support for different end users
- Touchscreen for easy operation and status display
- Working indicator light bar optional
- Emergency button for immediate stop
- Charge modules can be inserted easily
Operating Interface and Charger Details
The front panel and charger structure are designed for operator visibility, user access and serviceability.
Working Indicator Light
AC power ON is shown in green, DC output ON is shown in green, and fault condition is shown in red.
10" Touch Screen
Displays operating status, remaining charging time, failure information, parameter setting and charging status.
RFID Card Reader
Users can tap the RFID card at the reader to start and stop charging.
Emergency Stop Button
The emergency circuit breaker can stop the quick charger immediately in case of emergency.
Plug and Cable Storage
DC connector plug storage box and charging cable holder support cleaner cable management.
Forced Air Cooling
Air holes and fans provide forced air cooling for the charger.
Supply, Installation, Testing and Commissioning
180kW DC fast charging deployment requires proper electrical, civil, protection and communication planning. The incoming supply capacity, protection, earthing, cable route, charger location, network connection and payment / billing integration must be reviewed before installation.
Electrical Capacity Review
Review incoming three-phase supply, feeder capacity, transformer capacity, protection design and 180kW charger load requirement.
Site and Civil Planning
Confirm charger location, plinth, cable route, vehicle access, parking layout, bollards, waterproof shed requirement and service clearance.
Electrical Installation
Install power supply, protection, earthing, communication provisions and charger connection according to approved design.
Payment and Access Setup
Configure RFID access, payment terminal or billing platform integration where required by the operator.
Communication Setup
Configure OCPP 1.6 JSON communication through 4G, Ethernet or WiFi depending on site network availability.
Commissioning and Training
Check charger operation, touchscreen, connectors, emergency stop, signal lights, output function, communication and safety protection.
Suitable Applications
Service Stations
Suitable for petrol stations and service station operators adding DC fast charging facilities.
Highway Corridors
Supports public corridor charging along highways and intercity travel routes.
Busy Urban Areas
Suitable for city charging hubs, commercial car parks and high-demand EV charging locations.
Commercial Fleets
Supports faster charging for business EV fleets, logistics vehicles and operational vehicles.
EV Infrastructure Operators
Suitable for EVSE providers and charge point operators deploying public fast charging stations.
Multi-Brand EV Charging
Supports broad EV compatibility through CHAdeMO, CCS, GB/T and optional Type 1 / Type 2 configurations.
Technical Specifications
| AC Input Item | Specification |
|---|---|
| Rated Voltage | 3 phase 400VAC |
| Voltage Fluctuation Range | 400V ±10% |
| Number of Phases | Three-phase and four-line + PE |
| Rated Frequency | 50Hz or 60Hz |
| Frequency Fluctuation Range | ±5% |
| Input Power Factor | 0.99 in rated operation |
| Current THD | ≤5% |
| Input Power | 180kW |
| Grounding Detection | 30mA |
| Input Under-Voltage Protection | Yes |
| Harmonic Current | Total 5% or less |
| AC Output / DC Output Item | Specification |
|---|---|
| AC Output Power | 22kW option / 43kW option |
| AC Output Current | 32A for 22kW option / 63A for 43kW option |
| AC Interface | Type 2 |
| DC Rated Output Capacity | 180kW |
| DC Voltage Variable Range | 200–1000VDC |
| DC Output Current | 250A |
| Current Variable Range | 0–250A |
| Efficiency | 96% or more |
| Ripple Current | 6.0Ap-p or less |
| Protection | Output over-current protection / output short-circuit protection |
Structure, Connector and Communication
| Structure Item | Specification |
|---|---|
| Degree of Protection | IP54, waterproof shed recommended |
| Ambient Temperature | -20°C to +50°C |
| Operating Temperature Range | -25°C to +65°C |
| Storage Temperature | -30°C to +70°C |
| Dimensions | H1600 x W1070 x L690mm |
| Package Weight | 380kg, including 2 plugs, cables and modules |
| Certification | CE / IEC 61851 |
| Safety | Emergency stop button |
| Connector / Communication Item | Specification |
|---|---|
| Vehicle Connector | CCS + CCS / CHAdeMO + CCS; Tesla, GB/T and Type 1 / Type 2 optional |
| Charging Plug Place | Plug storage box for DC connector |
| Optional Connector Types | GB/T, CCS, CHAdeMO, AC Type 2 and Type 1 optional |
| Battery Communication Protocol | CAN2.0 for CHAdeMO / PLC for Combo |
| OCPP Protocol Version | OCPP 1.6 JSON |
| Network Communication | 4G, Ethernet, WiFi |
| Cooling Method | Forced air cooling |
| Work Indicator Light | AC power ON green / DC output ON green / fault red |
Commercial Charging Value
Higher Charging Capacity
180kW DC output supports faster charging sessions and higher utilisation for public and commercial charging sites.
Payment and Billing Support
Payment terminal, billing platform and RFID card access help operators manage secure charging and revenue collection.
Broad Connector Flexibility
CHAdeMO, CCS, GB/T, Tesla and AC Type 1 / Type 2 options make the station adaptable to different EV markets and deployment needs.
Product Summary
SETEC Power 180kW EV Fast Charging Station is a high-power commercial DC fast charger for service stations, highway charging corridors, urban charging hubs, fleet operators and EV infrastructure providers.
With 180kW DC output, SET750-180Y model configuration, CHAdeMO / CCS / GB/T / optional Type 2 support, optional 2 DC simultaneous charging, OCPP 1.6 JSON, 4G / Ethernet / WiFi, 10" touchscreen, RFID card reader, emergency stop, 200–1000VDC output range, 250A DC output current, 96% or higher efficiency and IP54 protection, it is suitable for demanding EV fast charging deployments.
Contact us for charger selection, site assessment, electrical capacity review, installation planning and commissioning support.
View more about SETEC 180kW DC Charger on main site
